Sign In | Join Free | My chinacomputerparts.com |
|
Brand Name : Inspired
Model Number : VHC-25
MOQ : 1pcs
Payment Terms : T/T(wire transfer), Western Union, Paypal
Packaging Details : Carton
Product Name : Inspired VHC-25 VHC25 Reusable Humidification Chamber
Brand : Inspired
Part No . : VHC-25 VHC25
Type : Reusable
Application : Adult
Fill water mode : Manually
Compressible Volume(empty) : 695ml
Compressible Volume(full) : 265ml
Maximum Water capacity : 430ml
Maximum Peak Flow : 90L/Min
Resistance (cmH2O) : <1CMh2O @60L/Min
Compliance (Empty) : <0.85 ml/cmH2O
Package : 12 pcs/carton
Warranty : 90 days
Inspired VHC-25 VHC25 Reusable Newborn Automatic Humidification Chamber
Inspired VHC-25 humidification chamber Specification
Type | Reusable |
Application | Adult |
Fill water mode | Manually |
Compressible Volume(empty) | 695ml |
Compressible Volume(full) | 265ml |
Maximum Water capacity | 430ml |
Maximum Peak Flow | 90L/Min |
Resistance (cmH2O) | <1CMh2O @60L/Min |
Compliance (Empty) | <0.85 ml/cmH2O |
Package | 12 pcs/carton |
Installing the VHB10A humidifier and chamber.
The maximum water level marked on the room. Please read the cavity description for detailed information on how to use the cavity.
Before use, if you have any questions about using the humidifier Please contact Vincent Medical Mfg. Company, Ltd. or your local area support.
The VHB10A is designed to be used for air supply such as the iVent 201 or other fans that meet the requirements of IEC 60601-1 and IEC 60601-1-2.
The following additional accessories are required: Humidification Chamber (e.g. VHC20), breathing circuit (e.g. 51003200).
warns:
Do not immerse the humidifier in liquids.
warns:
1) When installing the chamber, make sure the humidifier and chamber are lower than the patient.
2) When using a humidifier, if the chamber is tilted at an angle greater than the maximum allowable angle, the water in the chamber can flow directly into the patient's breathing circuit or air supply unit.
3) Do not add more water than the maximum level indicated on the humidifier.
4) Before turning on the humidifier, make sure that air is flowing through the chamber and the breathing circuit.
5) Do not use the device with flammable anesthetic gas, otherwise it may cause an explosion.
6) Use the device only with the humidification chamber and air tubing recommended by the manufacturer of Vincent Medical Manufacturing Co., Ltd.
If you're interested in Inspired VHC-25 VHC25 Reusable Humidification Chamber ,feel free to contact us .Thank you .
![]() |
Inspired VHC-25 VHC25 Patient Monitor Accessories Reusable Newborn Automatic Humidification Chamber Images |