Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466

Brand Name : Mindray

Model Number : CM1204

MOQ : 1

Payment Terms : T/T, Western Union,PayPal

Delivery Time : 3-5 working days

Product name : Mindray Cuff

Type : CM1204

Application : Patient Monitor

Warranty : 90days

Color : Gray

Functions : Monitor Patient's health condition,Print electrocardiogram

Usages : ICU, emergency, Patient Monitor, ICU Room and operating room

Measurement Site : Arm

After-sale Service : If we find non-human damage, we will be free for you to repair or returned

Limb Circumference (cm) : 33 to 47

Management Principles : Advanced technology, high-quality products, attentive service

Condition : In Good Order

Bladder Width (cm) : 18.3

MEANS OF TRANSPORT : Expressage

Contact Now

Hospital Medical Equipment PHiliphhilip Avalon FM20 FM30 fetal monitor Display assy 5 wire Part 453564435191

► Brief Introduction

The monitor uses the oscillometric method for measuring Non-Invasive Blood Pressure (NIBP). NIBP measurement is based on the principle that pulsatile blood flow through an artery creates oscillations of the arterial wall. The oscillometric device uses a blood pressure cuff to sense these oscillations that appear as tiny pulsations in cuff pressure. The oscillometric devices measure the amplitude of pressure changes in the occluding cuff as the cuff deflates from above systolic pressure. The amplitude suddenly increases as the pulse breaks through the occlusion in the artery. As the cuff pressure decreases further, the pulsations increase in amplitude, reach a maximum (which approximates to the mean pressure), and then diminish. The oscillometric method measures the mean pressure and determines the systolic and diastolic pressures.

NIBP monitoring is intended for adult, pediatric, and neonatal atients.

Model Patient Category Measurement Site Limb Circumference (cm) Bladder Width (cm) Part No.
CM1204 Large adult Arm 33 to 47 18.3 0010-30-12160

► NIBP Specifications

Static pressure range: 0 to 300 mmHg
Displayed Pressures: Systolic, Diastolic, Mean
Cuff inflation pressure(Default): Adult: 160±5 mmHg
Pediatric: 140±5 mmHg
Neonate: 90 ± 5 mmHg

► Placing the NIBP Cuff

To place the NIBP cuff, follow this procedure:

1. Verify that the patient category setting is correct.

2. Connect the air tubing to the NIBP connector on the monitor.

3. Select an appropriately sized cuff for the patient, and then wrap it around the limb directly over the patient’s skin as follows:

  • Determine the patient’s limb circumference.
  • Select an appropriate cuff by referring to the limb circumference marked on the cuff. The width of the cuff should be 40% (50% for neonates) of the limb circumference, or 2/3 of the length of the upper arm or the thigh. The inflatable part of the cuff should be long enough to encircle to overlap at least 50% to 80% of the limb.
  • Apply the cuff to the patient’s upper arm or leg and make sure the &PHiliphhilipi; marking on the cuff matches the artery location. The cuff should fit snugly, but with enough room for two fingers to be placed between the cuff and the patient’s arm (on adults), and loosely on neonates with little or no air present within the cuff. Otherwise it may cause discoloration and ischemia of the extremities. Make sure that the cuff index line falls within the range markings on the cuff. If it does not, use a cuff that fits better.
  • Middle of the cuff should be at the level of the right atrium of the heart. If it is not, use the measurement correction formula to correct the measurement.

4. Connect the cuff to the air tubing. Avoid compression or restriction of pressure tubes. Air must pass unrestricted through the tubing.

Starting and Stopping NIBP Measurements

Start and stop NIBP measurement by selecting the NIBP quick keys or from the NIBP dialog.

We seek for providing perfect service to the satisfaction of customers. Thank you for your time! If you are interested in Mindray NIBP Cuff CM1204 CE Cuff with connector Large Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466, welcome to place your orders. Early order early shipment!


Product Tags:

CM1204 Patient Monitor Parts

      

Mindray NIBP Cuff Patient Monitor Parts

      
China Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466 factory

Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)